Part No. | Inductance | Test Freq. | DCR(Ω) | Rated Current | Tolerance | Marking |
(μH ) | Max. | (A) | (±%) | |||
HCRI6D28T-1R0□ | 1 | 10 kHz,1 V | 0.024 | 3.5 | 30 | 1R0 |
HCRI6D28T-1R5□ | 1.5 | 10 kHz,1 V | 0.0195 | 3.4 | 30 | 1R5 |
HCRI6D28T-3R0□ | 3 | 10 kHz,1 V | 0.024 | 3 | 30 | 3R0 |
HCRI6D28T-3R3□ | 3.3 | 10 kHz,1 V | 0.025 | 3 | 30 | 3R3 |
HCRI6D28T-3R9□ | 3.9 | 10 kHz,1 V | 0.027 | 2.6 | 30 | 3R9 |
HCRI6D28T-4R7□ | 4.7 | 10 kHz,1 V | 0.031 | 2.4 | 30 | 4R7 |
HCRI6D28T-5R0□ | 5 | 10 kHz,1 V | 0.031 | 2.4 | 30 | 5R0 |
HCRI6D28T-6R0□ | 6 | 10 kHz,1 V | 0.035 | 2.25 | 30 | 6R0 |
HCRI6D28T-6R2□ | 6.2 | 10 kHz,1 V | 0.051 | 2.4 | 30 | 6R2 |
HCRI6D28T-6R8□ | 6.8 | 10 kHz,1 V | 0.05 | 2.15 | 30 | 6R8 |
HCRI6D28T-7R3□ | 7.3 | 10 kHz,1 V | 0.054 | 2.1 | 30 | 7R3 |
HCRI6D28T-8R6□ | 8.6 | 10 kHz,1 V | 0.058 | 1.85 | 30 | 8R6 |
HCRI6D28T-100□ | 10 | 10 kHz,1 V | 0.065 | 1.7 | 20,30 | 100 |
HCRI6D28T-120□ | 12 | 10 kHz,1 V | 0.07 | 1.55 | 20,30 | 120 |
HCRI6D28T-150□ | 15 | 10 kHz,1 V | 0.084 | 1.4 | 20,30 | 150 |
HCRI6D28T-180□ | 18 | 10 kHz,1 V | 0.095 | 1.32 | 20,30 | 180 |
HCRI6D28T-220□ | 22 | 10 kHz,1 V | 0.128 | 1.2 | 20,30 | 220 |
HCRI6D28T-270□ | 27 | 10 kHz,1 V | 0.142 | 1.05 | 20,30 | 270 |
HCRI6D28T-330□ | 33 | 10 kHz,1 V | 0.165 | 0.97 | 20,30 | 330 |
HCRI6D28T-390□ | 39 | 10 kHz,1 V | 0.21 | 0.86 | 20,30 | 390 |
HCRI6D28T-470□ | 47 | 10 kHz,1 V | 0.238 | 0.8 | 20,30 | 470 |
HCRI6D28T-560□ | 56 | 10 kHz,1 V | 0.277 | 0.73 | 20,30 | 560 |
HCRI6D28T-680□ | 68 | 10 kHz,1 V | 0.304 | 0.65 | 20,30 | 680 |
HCRI6D28T-820□- | 82 | 10 kHz,1 V | 0.39 | 0.6 | 20,30 | 820 |
HCRI6D28T-101□ | 100 | 10 kHz,1 V | 0.535 | 0.54 | 20,30 | 101 |
HCRI6D28T-121□ | 120 | 10 kHz,1 V | 0.6 | 0.4 | 20,30 | 121 |
HCRI6D28T-221□ | 220 | 10 kHz,1 V | 1.3 | 0.3 | 20,30 | 221 |
NOTE: □-tolerance M=±20% / T=±30% | ||||||
1.Operating temperature range -40℃~125℃(Including self – temperature rise) | ||||||
2.Rate current: The rate current indicates the current when the inductance decreases to 65% over of | ||||||
it’s nominal value or D.C.current when the temperature rising △T=40℃ lower, whichever is lower. | ||||||
3.RDC test method: place testing device to the 2 solder ends of wounding and test the value. | ||||||